52 lines
3.1 KiB
Plaintext
52 lines
3.1 KiB
Plaintext
#notes label(help)
|
|
A pump stack is useful for moving water or magma up through the z-levels.
|
|
""
|
|
To use these blueprints:
|
|
- Measure how many z-levels the pump stack should span.
|
|
"- Position the cursor on the bottom level of the future pump stack. It should be on the z-level just above the liquid you want to pump. Run ""quickfort run library/pump_stack.csv -n /dig2SN"" to see where the suction hole will end up. Replace ""run"" with ""undo"" in the previous command to clean up."
|
|
"- If you need an East-West pump stack, or if you need the staircase in another spot, use the ""--transform"" commandline option to alter the blueprint to your needs. For example: ""quickfort run library/pump_stack.csv -n /dig2SN --transform rotcw,fliph"". If you use a transformation, be sure to use the same option for the remaining commandlines."
|
|
"- Once you have everything lined up, run ""quickfort run library/pump_stack.csv -n /dig2SN --repeat up,20"" to designate the entire pump stack for digging. Replace that last ""20"" with the height of your pump stack divided by 2 (since each repetition of /dig2SN is two z-levels high). If the height ends up being one too many at the top, manually undesignate the top level."
|
|
"- Since you do not need to transmit power down below the lowest level, replace the channel designation on the middle tile of the bottom-most pump stack level with a regular dig designation. Likewise, replace the Up/Down staircase designation on the lowest level with an Up staircase designation."
|
|
"- After the stack is dug out, prepare for building by setting the buildingplan plugin material filters for screw pumps (b-M-s-M). If you are planning to move magma, be sure to select magma-safe materials."
|
|
"- Finally, position the cursor back on the access stairs on the lowest level and run ""quickfort run library/pump_stack.csv -n /build2SN --repeat up,20"" (with 20 replaced with your desired repetition count and with your --transform command, if any)."
|
|
""
|
|
"Sometimes, a screw pump will spontaneously deconstruct while you are building the stack. This will reduce the efficiency of the stack a little, but it's nothing to worry about. Just re-run the /build2SN blueprint over the entire stack to ""fix up"" any broken pieces. The blueprint will harmlessly skip over any correctly-built screw pumps."
|
|
""
|
|
See the wiki for more info on pump stacks: https://dwarffortresswiki.org/index.php/Screw_pump#Pump_stack
|
|
#dig label(digSN) start(2;4;on access stairs) hidden() for a pump from south level
|
|
|
|
,,,d
|
|
,,,h
|
|
,i,d,d
|
|
,,,h
|
|
|
|
#dig label(digNS) start(2;4;on access stairs) hidden() for a pump from north level
|
|
|
|
,,,h
|
|
,d,d,d
|
|
,i,,h
|
|
,,,d
|
|
|
|
#meta label(dig2SN) start(at the bottom level on the access stairs) 2 levels of pump stack - bottom level pumps from the south
|
|
/digSN
|
|
#<
|
|
/digNS
|
|
#build label(buildSN) start(2;4;on access stairs) hidden() for a pump from south level
|
|
|
|
,,,`
|
|
,,,~
|
|
,`,`,Msm
|
|
,,,`
|
|
|
|
#build label(buildNS) start(2;4;on access stairs) hidden() for a pump from north level
|
|
|
|
,,,`
|
|
,`,`,~
|
|
,`,,Msu
|
|
,,,`
|
|
|
|
#meta label(build2SN) start(at the bottom level on the access stairs) 2 levels of pump stack - bottom level pumps from the south
|
|
/buildSN
|
|
#<
|
|
/buildNS
|